NiMH Pulse Battery Chargers,
Switchmode-Type
High
quality and low prices
Click on a Model number or Series number
below to get more
detailed
information on that Charger Model number or Series number
(Listed in order of "No.
of Cells", ascending, in each Category)
Catalog
Models of NiMH Pulse-Type Battery Chargers:
Click on the"selections"
immediately below to move to the selected types on this same page.
Type
|
Output Wattage
|
Desktop
NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Plastic Case
GY
|
100
|
Open-Frame
NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Case PE
|
100
|
Desktop
NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Metal Case TA
(internal fan)
|
170
|
Enclosed
NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Metal Case TA
(internal fan)
|
170
|
Enclosed
NiMH Battery Chargers, Switch-Mode Regulated , Pulse Type, Metal Case TD
(internal fan)
(product in development)
|
800
|
Rain-Resistant,
Enclosed NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Metal
Case VR (internal fan)
(product in development)
|
1175
|
Rain-Resistant,
Enclosed NiMH Battery Chargers, Switch-Mode Regulated, Pulse Type, Metal
Case VS (internal fan)
(product in development)
|
1175
|
Microprocessor-based,
Enclosed NiMH Battery Chargers, Switch-Mode Regulated, Various Charge Algorithms,
Rain-Resistant
Metal Case VS (internal fan)
(product in development)
|
1175
|
Desktop
NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Plastic Case GY, 100 Watt
Click
here to see pictures of these chargers (30 sec load time)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector , with 2-conductor power output cable with connector
on end to connect to a separate mating cable (See Note 3 below for "Accessory
Items") which has ring tongues on the ends to connect to the respective
(+) and (-) battery posts, and with 2-conductor thermistor cable with connector
on end to connect to a separate mating cable (See Note 3 below for "Accessory
Items") which has a isolated 10K thermistor in a ring tongue barrel for
connection to one of the (+) battery posts (which is close to internal
battery temperature).
Size: 7.03" long x 3.75"
wide x 2.28" high. Weight: 1.75 lbs. (approx.)
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
5 to 8 cells
|
6 to 9.6
|
S4DB14.1GY
|
14.7v/6.0A,
GY
|
1.4AH @ 4C; 2.8AH @ 2C; 4.4AH @ 1.3C; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/1.5; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/6; 39AH @ C/7;
47AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
6 to 10 cells
|
7.2 to 12
|
S4DB14.1GY
|
16.8v/5.3A,
GY
|
1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/2; 14AH @ C/3; 22AH @ C/5; 31AH @ C/6; 39AH @ C/8; 47AH
@ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
9 to 15 cells
|
13.2 to 18
|
S4DB14.1GY
|
25.5v/3.9A,
GY
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1.5;
5AH @ C/1.5; 7AH @ C/2; 9AH @ C/2.5; 14AH @ C/4; 22AH @ C/6; 31AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
10 to 17 cells
|
12 to 20.4
|
S4DB14.1GY
|
29.4V/3.4A,
GY
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/1.5; 7AH @ C/2.5; 9AH @ C/3; 14AH @ C/5; 22AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
12 to 20 cells
|
19.2 to 24
|
S4DB14.1GY
|
33.6v/3.0A,
GY
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/2; 7AH @ C/2.5; 9AH @ C/3.0; 14AH @ C/5; 22AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
15 to 26 cells
|
18 to 31.2
|
S4DB14.1GY
|
44.1v/2.3A,
GY
|
1.2AH @ 1.3C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2;
5AH @ C/2.5; 7AH @ C/4; 9AH @ C/4; 14AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
18 to 30 cells
|
25.2 to 36
|
S4DB14.1GY
|
50.4v/2.0A,
GY
|
1.2AH @ 1.3C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2.5;
5AH @ C/2.5; 7AH @ C/4; 9AH @ C/5; 14AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
21 to 35 cells
|
25.2 to 42
|
S4DB14.1GY
|
58.8v/1.7A,
GY
|
1.2AH @ 1.3C; 1.4AH @ C/1; 2.8AH @ C/2; 4.4AH @ C/3;
5AH @ C/3; 7AH @ C/5; 9AH @ C/6; 14AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
24 to 40 cells
|
37.2 to 48
|
S4DB14.1GY
|
67.2v/1.5A,
GY
|
1.2AH @ C/1; 1.4AH @ C/1; 2.8AH @ C/2; 4.4AH @ C/3; 5AH
@ C/4; 7AH @ C/5; 9AH @ C/6. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also, if "Option" for thermistor
detection in the charger is chosen, then fast charge is also terminated
by using (2) excessive temperature slope detection (rate of change in battery
temperature) determined by measuring the rate of change in resistance of
the thermistor. Safety backups to the primary fast charge termination method
above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded (Only if "Option" for thermistor detection in the charger is
chosen).
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Open-Frame
NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Case PE, 100 Watt
Click
here to see pictures of these chargers (30 sec load time)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), with
0.25" Fast-ons for input and output connections on charger unit, and with
0.14" Fast-ons for connecting wires needed to connect to an isolated 10K
thermistor in a ring tongue barrel to mount to one of the (+) battery posts
(which is close to the internal battery temperature).
Size: 6.50" long x 3.30"
wide x 1.94" high. Weight: 1.5 lbs. (approx.)
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
5 to 8 cells
|
6 to 9.6
|
S4DB14.1PE
|
14.7v/6.0A,
PE
|
1.4AH @ 4C; 2.8AH @ 2C; 4.4AH @ 1.3C; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/1.5; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/6; 39AH @ C/7;
47AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
6 to 10 cells
|
7.2 to 12
|
S4DB14.1PE
|
16.8v/5.3A,
PE
|
1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/2; 14AH @ C/3; 22AH @ C/5; 31AH @ C/6; 39AH @ C/8; 47AH
@ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
9 to 15 cells
|
13.2 to 18
|
S4DB14.1PE
|
25.5v/3.9A,
PE
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1.5;
5AH @ C/1.5; 7AH @ C/2; 9AH @ C/2.5; 14AH @ C/4; 22AH @ C/6; 31AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
10 to 17 cells
|
12 to 20.4
|
S4DB14.1PE
|
29.4V/3.4A,
PE
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/1.5; 7AH @ C/2.5; 9AH @ C/3; 14AH @ C/5; 22AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
12 to 20 cells
|
19.2 to 24
|
S4DB14.1PE
|
33.6v/3.0A,
PE
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/2; 7AH @ C/2.5; 9AH @ C/3.0; 14AH @ C/5; 22AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
15 to 26 cells
|
18 to 31.2
|
S4DB14.1PE
|
44.1v/2.3A,
PE
|
1.2AH @ 1.3C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2;
5AH @ C/2.5; 7AH @ C/4; 9AH @ C/4; 14AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
18 to 30 cells
|
25.2 to 36
|
S4DB14.1PE
|
50.4v/2.0A,
PE
|
1.2AH @ 1.3C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2.5;
5AH @ C/2.5; 7AH @ C/4; 9AH @ C/5; 14AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
21 to 35 cells
|
25.2 to 42
|
S4DB14.1PE
|
58.8v/1.7A,
PE
|
1.2AH @ 1.3C; 1.4AH @ C/1; 2.8AH @ C/2; 4.4AH @ C/3;
5AH @ C/3; 7AH @ C/5; 9AH @ C/6; 14AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
24 to 40 cells
|
37.2 to 48
|
S4DB14.1PE
|
67.2v/1.5A,
PE
|
1.2AH @ C/1; 1.4AH @ C/1; 2.8AH @ C/2; 4.4AH @ C/3; 5AH
@ C/4; 7AH @ C/5; 9AH @ C/6. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
0.25" Fastons for Input and Output; 0.14" for thermistor
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also, if "Option" for thermistor
detection in the charger is chosen, then fast charge is also terminated
by using (2) excessive temperature slope detection (rate of change in battery
temperature) determined by measuring the rate of change in resistance of
the thermistor. Safety backups to the primary fast charge termination method
above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded (Only if "Option" for thermistor detection in the charger is
chosen).
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Desktop
NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Metal Case TA, 170 watt (internal
fan)
Click
here to see pictures of these chargers (30 sec load time)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector , with 2-conductor power output cable with connector
on end to connect to a separate mating cable (See Note 3 below for "Accessory
Items") which has ring tongues on the ends to connect to the respective
(+) and (-) battery posts, and with 2-conductor thermistor cable with connector
on end to connect to a separate mating cable (See Note 3 below for "Accessory
Items") which has a isolated 10K thermistor in a ring tongue barrel for
connection to one of the (+) battery posts (which is close to internal
battery temperature).
Size: 7.87" long x 3.94"
wide x 3.15" high. Weight: 3.25 lbs. (approx.)
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
5 to 8 cells
|
6 to 9.6
|
S4DB14.1TA
|
14.7v/11.5A,
TA
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ 2C; 7AH @ 1.3C; 9AH @ C/1;
14AH @ C/1.5; 22AH @ C/2; 31AH @ C/3; 39AH @ C/4; 47AH @ C/4; 70AH @ C/7;
100AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
6 to 10 cells
|
7.2 to 12
|
S4DB14.1TA
|
16.8v/10.0A,
TA
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ C/2; 7AH @ 1.3C; 9AH @
C/1; 14AH @ C/1.5; 22AH @ C/2.5; 31AH @ C/4; 39AH @ C/4; 47AH @ C/5; 70AH
@ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
9 to 15 cells
|
13.2 to 18
|
S4DB14.1TA
|
25.5v/6.7A,
TA
|
2.8AH @ 2C; 4.4AH @ 1.3C; 5AH @ C/1.3; 7AH @ C/1; 9AH
@ C/1.5; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/5; 47AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
10 to 17 cells
|
12 to 20.4
|
S4DB14.1TA
|
29.4V/5.8A,
TA
|
1.4AH @ 4C; 2.8AH @ 2C; 4.4AH @ C/1.3; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/2; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/6; 47AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
12 to 20 cells
|
19.2 to 24
|
S4DB14.1TA
|
33.6v/5.1A,
TA
|
1.2AH @ 4C; 1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1; 5AH
@ C/1; 7AH @ C/1.5; 9AH @ C/2; 14AH @ C/3; 22AH @ C/5; 31AH @ C/6. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
15 to 26 cells
|
18 to 31.2
|
S4DB14.1TA
|
44.1v/3.8A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1.3; 4.4AH @ C/1.5;
5AH @ C/1.5; 7AH @ C/2; 9AH @ C/2.5; 14AH @ C/4; 22AH @ C/6; 31AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
18 to 30 cells
|
25.2 to 36
|
S4DB14.1TA
|
50.4v/3.4A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/1.5; 7AH @ C/2.5; 9AH @ C/3; 14AH @ C/5; 22AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
21 to 35 cells
|
25.2 to 42
|
S4DB14.1TA
|
58.8v/2.9A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/2; 5AH
@ C/2; 7AH @ C/2.5; 9AH @ C/4; 14AH @ C/5; 22AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
24 to 40 cells
|
37.2 to 48
|
S4DB14.1TA
|
67.2v/2.5A,
TA
|
1.2AH @ 2C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2;
5AH @ C/2; 7AH @ C/3; 9AH @ C/4; 14AH @ C/6; 22AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Enclosed
NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Metal Case TA, 170 Watt (internal
fan)
Click
here to see pictures of these chargers (30 sec load time)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector and Anderson Power Pole output connector on charger
unit for connection of the customer furnished output power cable with mating
connector, and with separate DIN connector for connecting a customer-furnished
2-wire cable with mating connector and with an isolated thermistor in a
ring tongue barrel on the end for connection to one of the (+) battery
posts (which is close to the internal battery temperature).
(See Note 3 below for "Accessory Items").
Size: 7.87" long x 3.94"
wide x 3.15" high. Weight: 3.25 lbs. (approx.)
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
5 to 8 cells
|
6 to 9.6
|
S4EB14.1TA
|
14.7v/11.5A,
TA
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ 2C; 7AH @ 1.3C; 9AH @ C/1;
14AH @ C/1.5; 22AH @ C/2; 31AH @ C/3; 39AH @ C/4; 47AH @ C/4; 70AH @ C/7;
100AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
6 to 10 cells
|
7.2 to 12
|
S4EB14.1TA
|
16.8v/10.0A,
TA
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ C/2; 7AH @ 1.3C; 9AH @
C/1; 14AH @ C/1.5; 22AH @ C/2.5; 31AH @ C/4; 39AH @ C/4; 47AH @ C/5; 70AH
@ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
9 to 15 cells
|
13.2 to 18
|
S4EB14.1TA
|
25.5v/6.7A,
TA
|
2.8AH @ 2C; 4.4AH @ 1.3C; 5AH @ C/1.3; 7AH @ C/1; 9AH
@ C/1.5; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/5; 47AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
10 to 17 cells
|
12 to 20.4
|
S4EB14.1TA
|
29.4V/5.8A,
TA
|
1.4AH @ 4C; 2.8AH @ 2C; 4.4AH @ C/1.3; 5AH @ C/1; 7AH
@ C/1.5; 9AH @ C/2; 14AH @ C/2.5; 22AH @ C/4; 31AH @ C/6; 47AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
12 to 20 cells
|
19.2 to 24
|
S4EB14.1TA
|
33.6v/5.1A,
TA
|
1.2AH @ 4C; 1.4AH @ 2C; 2.8AH @ 1.3C; 4.4AH @ C/1; 5AH
@ C/1; 7AH @ C/1.5; 9AH @ C/2; 14AH @ C/3; 22AH @ C/5; 31AH @ C/6. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
15 to 26 cells
|
18 to 31.2
|
S4EB14.1TA
|
44.1v/3.8A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1.3; 4.4AH @ C/1.5;
5AH @ C/1.5; 7AH @ C/2; 9AH @ C/2.5; 14AH @ C/4; 22AH @ C/6; 31AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
18 to 30 cells
|
25.2 to 36
|
S4EB14.1TA
|
50.4v/3.4A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/1.5; 5AH
@ C/1.5; 7AH @ C/2.5; 9AH @ C/3; 14AH @ C/5; 22AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
21 to 35 cells
|
25.2 to 42
|
S4EB14.1TA
|
58.8v/2.9A,
TA
|
1.2AH @ 2C; 1.4AH @ 2C; 2.8AH @ C/1; 4.4AH @ C/2; 5AH
@ C/2; 7AH @ C/2.5; 9AH @ C/4; 14AH @ C/5; 22AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
24 to 40 cells
|
37.2 to 48
|
S4EB14.1TA
|
67.2v/2.5A,
TA
|
1.2AH @ 2C; 1.4AH @ 1.3C; 2.8AH @ C/1.5; 4.4AH @ C/2;
5AH @ C/2; 7AH @ C/3; 9AH @ C/4; 14AH @ C/6; 22AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
2-wire power: Optional:2-wire for thermistor
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Enclosed
NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Metal Case TD, 800 Watt (internal
fan)
(in development)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector and Anderson Power Pole output connector on charger
unit for connection of the customer furnished output power cable with mating
connector, and with separate DIN connector for connecting a customer-furnished
2-wire cable with mating connector and with an isolated thermistor in a
ring tongue barrel on the end for connection to one of the (+) battery
posts (which is close to the internal battery temperature).
(See Note 3 below for "Accessory Items").
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
5 to 8 cells
|
6 to 9.6
|
S4EB14.1TD
|
14.7v/20.0A,
TD
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1.5;
31AH @ C/2; 39AH @ C/2; 47AH @ C/2.5; 70AH @ C/4; 100AH @ C/5; 150AH @
C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
5 to 8 cells
|
6 to 9.6
|
S4EB14.1TD
|
14.7v/30.0A,
TD
|
9AH @ 2C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1.5; 47AH @ C/2; 70AH @ C/2.5; 100AH @ C/4; 150AH @ C/5; 200AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
5 to 8 cells
|
6 to 9.6
|
S4EB14.1TD
|
14.7v/40.0A,
TD
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
6 to 10 cells
|
7.2 to 12
|
S4EB14.1TD
|
16.8v/35.0A,
TD
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1.5; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/3; 150AH @ C/5; 200AH @ C/6;
300AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
9 to 15 cells
|
13.2 to 18
|
S4EB14.1TD
|
25.5v/30.0A,
TD
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1.5; 47AH @ C/2; 70AH @ C/2.5; 100AH @ C/4; 150AH @ C/5; 200AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
10 to 17 cells
|
12 to 20.4
|
S4EB14.1TD
|
29.4V/27.0A,
TD
|
7AH @ 4C; 9AH @ 2C; 14AH @ 2C; 22AH @ C/1; 31AH @ C/1.5;
47AH @ C/2; 70AH @ C/3; 100AH @ C/4; 150AH @ C/6; 200AH @ C/8. . |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
12 to 20 cells
|
19.2 to 24
|
S4EB14.1TD
|
33.6v/23.0A,
TD
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1;
31AH @ C/1.5; 47AH @ C/2; 70AH @ C/3; 100AH @ C/5; 150AH @ C/7; 200AH @
C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
15 to 26 cells
|
18 to 31.2
|
S4EB14.1TD
|
44.1v/18.0A,
TD
|
4.4AH @ 4C; 5AH @ 2C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C;
22AH @ C/1; 31AH @ C/2; 47AH @ C/3; 70AH @ C/4; 100AH @ C/6; 150AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3r
|
18 to 30 cells
|
25.2 to 36
|
S4EB14.1TD
|
50.4v/15.8A,
TD
|
4.4AH @ 2C; 5AH @ 2C; 7AH @ 2C; 9AH @ 1.3C; 14AH @ C/1;
22AH @ C/1.5; 31AH @ C/2; 47AH @ C/3; 70AH @ C/5; 100AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
21 to 35 cells
|
25.2 to 42
|
S4EB14.1TD
|
58.8v/13.6A,
TD
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ 2C; 7AH @ 1.3C; 9AH
@ 1.3C; 14AH @ C/1; 22AH @ C/2; 31AH @ C/2.5; 47AH @ C/4; 70AH @ C/6; 100AH
@ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
24 to 40 cells
|
37.2 to 48
|
S4EB14.1TD
|
67.2v/11.9A,
TD
|
2.8AH @ 4C; 4.4AH @ 2C; 5AH @ 2C; 7AH @ 1.3C; 9AH @ 1.3C;
14AH @ C/1.5; 22AH @ C/2; 31AH @ C/3; 47AH @ C/4; 70AH @ C/6; 100AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Rain-Resistant,
Enclosed NiCd Battery Chargers, Switchmode Regulated, Pulse Type,
Metal Case VR, 1175 Watt (internal
fan)
(in development)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector and Anderson Power Pole output connector on charger
unit for connection of the customer furnished output power cable with mating
connector, and with separate DIN connector for connecting a customer-furnished
2-wire cable with mating connector and with an isolated thermistor in a
ring tongue barrel on the end for connection to one of the (+) battery
posts (which is close to the internal battery temperature).
(See Note 3 below for "Accessory Items").
Size: 13.00" long x 5.75"
wide x 4.25" high. Weight: 6.9 lbs. (approx.)
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
6 to 10 cells
|
7.2 to 12
|
S4EB14.1VR
|
16.8v/45.0A,
VR
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
9 to 15 cells
|
13.2 to 18
|
S4EB14.1VR
|
25.5v/45.0A,
VR
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
10 to 17 cells
|
12 to 20.4
|
S4EB14.1VR
|
29.4V/40.0A,
VR
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
12 to 20 cells
|
19.2 to 24
|
S4EB14.1VR
|
33.6v/35.0A,
VR
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH
@ C/1.5; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/3; 150AH @ C/5; 200AH @ C/6;
300AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
15 to 26 cells
|
18 to 31.2
|
S4EB14.1VR
|
44.1v/26.6A,
VR
|
7AH @ 4C; 9AH @ 2C; 14AH @ 2C; 22AH @ C/1; 31AH @ C/1.5;
47AH @ C/2; 70AH @ C/3; 100AH @ C/4; 150AH @ C/6; 200AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
18 to 30 cells
|
25.2 to 36
|
S4EB14.1VR
|
50.4v/23.3A,
VR
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1;
31AH @ C/1.5; 47AH @ C/2; 70AH @ C/3; 100AH @ C/5; 150AH @ C/7; 200AH @
C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
21 to 35 cells
|
25.2 to 42
|
S4EB14.1VR
|
58.8v/20.0A,
VR
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/2.5; 70AH @ C/4; 100AH @ C/5; 150AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
24 to 40 cells
|
37.2 to 48
|
S4EB14.1VR
|
67.2v/17.5A,
VR
|
5AH @ 2C; 7AH @ 2C; 9AH @ 1.3C; 14AH @ C/1; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/3; 70AH @ C/4; 100AH @ C/6; 150AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Rain-Resistant,
Enclosed NiMH Battery Chargers, Switchmode Regulated, Pulse Type,
Metal Case VS, 1175 Watt (internal
fan)
(in development)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector and Anderson Power Pole output connector on charger
unit for connection of the customer furnished output power cable with mating
connector, and with separate DIN connector for connecting a customer-furnished
2-wire cable with mating connector and with an isolated thermistor in a
ring tongue barrel on the end for connection to one of the (+) battery
posts (which is close to the internal battery temperature).
(See Note 3 below for "Accessory Items").
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
6 to 10 cells
|
7.2 to 12
|
S4EB14.1VS
|
16.8v/45.0A,
VS
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
9 to 15 cells
|
13.2 to 18
|
S4EB14.1VS
|
25.5v/45.0A,
VS
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
10 to 17 cells
|
12 to 20.4
|
S4EB14.1VS
|
29.4V/40.0A,
VS
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
12 to 20 cells
|
19.2 to 24
|
S4EB14.1VS
|
33.6v/35.0A,
VS
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH
@ C/1.5; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/3; 150AH @ C/5; 200AH @ C/6;
300AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
15 to 26 cells
|
18 to 31.2
|
S4EB14.1VS
|
44.1v/26.6A,
VS
|
7AH @ 4C; 9AH @ 2C; 14AH @ 2C; 22AH @ C/1; 31AH @ C/1.5;
47AH @ C/2; 70AH @ C/3; 100AH @ C/4; 150AH @ C/6; 200AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
18 to 30 cells
|
25.2 to 36
|
S4EB14.1VS
|
50.4v/23.3A,
VS
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1;
31AH @ C/1.5; 47AH @ C/2; 70AH @ C/3; 100AH @ C/5; 150AH @ C/7; 200AH @
C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
21 to 35 cells
|
25.2 to 42
|
S4EB14.1VS
|
58.8v/20.0A,
VS
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/2.5; 70AH @ C/4; 100AH @ C/5; 150AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
24 to 40 cells
|
37.2 to 48
|
S4EB14.1VS
|
67.2v/17.5A,
VS
|
5AH @ 2C; 7AH @ 2C; 9AH @ 1.3C; 14AH @ C/1; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/3; 70AH @ C/4; 100AH @ C/6; 150AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Smart IC
|
Customer-furnished
See Note 3
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiMH Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiMH battery chargers.
Back
to top, "Catalog Models" selections
Microprocessor-Based,
Enclosed NiMH Battery Chargers, Switchmode Regulated,
Various Charge Algorithms (pulse
charger one shown below),
Rain-Resistant Metal Case VS,
1175 Watt (internal fan)
(in development)
Models with 4-Stage Pulse Charge, Multiple Methods of
Charge Termination (See Note 1 under table), and with
IEC 320 input connector and Anderson Power Pole output connector on charger
unit for connection of the customer furnished output power cable with mating
connector, and with separate DIN connector for connecting a customer-furnished
2-wire cable with mating connector and with an isolated thermistor in a
ring tongue barrel on the end for connection to one of the (+) battery
posts (which is close to the internal battery temperature).
(See Note 3 below for "Accessory Items").
Note: These charger models
can also be used with NiCd battery systems if customer wants to use a thermistor
temperature sensor for protection when charging NiCd batteries.
Knowing your battery's "number
of cells and AH rating", look in the 5th column of table below for the
AH rating to determine the "Charger Series and a model (charge rate,C)"
that will be suitable for your battery and your application!
No. of Battery Cells
|
Battery Volts
|
Model or Series
|
Charger Output Voltage/ Current, Case
Size
|
AH Ratings (approximate) of battery and the associated
charge rates that are suited for Charger (by model selection), (See Note
2)
|
Input Voltage (vac)
|
Regulation
Method/ Charge Control Method |
Output Cables(s)
(see Note 3) |
6 to 10 cells
|
7.2 to 12
|
S4EB16.14.1VS
|
16.8v/45.0A,
VS
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
9 to 15 cells
|
13.2 to 18
|
S4EB16.14.1VS
|
25.5v/45.0A,
VS
|
11AH @ 4C; 14AH @ 2C; 22AH @ 2C; 31AH @ 1.3C; 39AH @
C/1; 47AH @ C/1; 70AH @ C/1.5; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/7. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
10 to 17 cells
|
12 to 20.4
|
S4EB16.14.1VS
|
29.4V/40.0A,
VS
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH @
C/1; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/2.5; 150AH @ C/4; 200AH @ C/5;
300AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
12 to 20 cells
|
19.2 to 24
|
S4EB16.14.1VS
|
33.6v/35.0A,
VS
|
9AH @ 4C; 14AH @ 2C; 22AH @ 1.3C; 31AH @ C/1; 39AH
@ C/1.5; 47AH @ C/1.5; 70AH @ C/2; 100AH @ C/3; 150AH @ C/5; 200AH @ C/6;
300AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
15 to 26 cells
|
18 to 31.2
|
S4EB16.14.1VS
|
44.1v/26.6A,
VS
|
7AH @ 4C; 9AH @ 2C; 14AH @ 2C; 22AH @ C/1; 31AH @ C/1.5;
47AH @ C/2; 70AH @ C/3; 100AH @ C/4; 150AH @ C/6; 200AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
18 to 30 cells
|
25.2 to 36
|
S4EB16.14.1VS
|
50.4v/23.3A,
VS
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1;
31AH @ C/1.5; 47AH @ C/2; 70AH @ C/3; 100AH @ C/5; 150AH @ C/7; 200AH @
C/9. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
21 to 35 cells
|
25.2 to 42
|
S4EB16.14.1VS
|
58.8v/20.0A,
VS
|
5AH @ 4C; 7AH @ 2C; 9AH @ 2C; 14AH @ 1.3C; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/2.5; 70AH @ C/4; 100AH @ C/5; 150AH @ C/8. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
24 to 40 cells
|
37.2 to 48
|
S4EB16.14.1VS
|
67.2v/17.5A,
VS
|
5AH @ 2C; 7AH @ 2C; 9AH @ 1.3C; 14AH @ C/1; 22AH @ C/1.5;
31AH @ C/2; 47AH @ C/3; 70AH @ C/4; 100AH @ C/6; 150AH @ C/9. |
90 to 264 (universal)
|
Switch-mode/
Microprocessor
|
Customer-furnished
See Note 3
|
Notes:
1) Termination of Fast Charge on the 4-stage Fast Chargers
is done primarily by using (1) dynamic inflection point voltage slope detection
(negative 1st derivative of dV/dt) and also by using (2) excessive temperature
slope detection (rate of change in battery temperature) determined by measuring
the rate of change in resistance of the thermistor. Safety backups to the
primary fast charge termination method above include:
a) "Negative delta V" and "peak voltage (or zero delta V)" detection
and
b) Timer controlled fast charge termination.
c) Termination if the set point for "maximum allowable battery temperature"
is exceeded.
2) The battery AH rating divided by the charge
current for the respective model will determine the selection of the "C
rate" for the model to be ordered. Charge rates of 4C, 2C, 1.3C, C/1, C/1.5,
C/2, C/2.5, C/3, C/4, C/5, C/6, C/7, C/8, and C/9 are "standard rates"
available. Custom "C rates", up to C/9, also available for
large quantity applications. Call for technical support when in question.
3) Click on Accessory
Items for NiCd Battery Chargers to go
to a separate page on this web site for some accessories that can be purchased
to use with the NiZn battery chargers.
Back
to top, "Catalog Models" selections
Custom Designs of NiMH Pulse-Type
Battery Chargers:
If you need a custom design,
ask us to quote on your special requirements!
E-mail: sales @dynage.com
|