| High Voltage
Transformers, 50/60/400 Hz & Pulse High
quality and low prices
 Click on a Model number or Series number
below to get more detailed information
on that HV Transformer Model number or
Series number
 
 Custom Designs of HV Transformers,
50/60/400 Hz & Pulse Types:
     
See products already designed or under development in tables below.
Ask us to quote on your custom design requirements!
 E-mail: sales@dynage.com
 
 
 HV Power Transformers (for Ozone
Generators):
 Open Construction, Varnish-Impregnated Types
 
| VA Out
 | Model or Series | Output ac (rms) voltage and current ratings | Input Voltage/Hz
 | Other Features
or Comments |  
| 100 | V1TH1MB | Secondary start lead is connected
to "ground". 1,000 vac, 100 mA.
 | 120/60 or 240/50
 | Size (inches): 3.30 x 3.75 x 4.25 |  
| 150 | V1TH1MC | Secondary start lead is connected
to "ground". 2,000 vac, 75 mA.
 | 120/60 | Size (inches): 3.80 x 3.75 x 4.25 |  
| 200 | V1TH1MD | Secondary start lead is connected
to "ground". 1,000 vac, 200 mA; 2,000 vac, 100
mA;
 3,000 vac, 67 mA; 4,000 vac, 50
mA.
 | 120/60 or 240/50
 | Size (inches): 4.30 x 3.75 x 4.25 |  
| 200 | V1TH2MD | Center-tap of Secondary is connected
to "ground". 2,000 vac Center-tapped, 100 mA;
 4,000 vac Center-tapped, 50 mA
 | 120/60 or 240/50
 | Size (inches): 4.30 x 3.75 x 4.25 |  
| 100 | V1TH3MB | Secondary is "floating". 1,000 vac, 100 mA.
 | 120/60 or 240/50
 | Size (inches): 3.30 x 3.75 x 4.25 |  
| 200 | V1TH3MD | Secondary is "floating". 1,000 vac, 200 mA; 2,000 vac, 100
mA.
 | 120/60 or 240/50
 | Size (inches): 4.30 x 3.75 x 4.25 |  
| 200 | 301TH-096 | Secondary start lead
is connected to "ground". 10,000 vac (RMS) @ 20 mA (Ozone Cell Load}.
 | 115vac +12%, -9%
 60 Hz
 | Size: 7.55" L x 3.75" W x 5.25" H & four (4) angle brackets on the base for mounting.
 This model is in final development stage.
 |  
| 500 | 301TH-041 | Secondary start lead is connected
to "ground". 5,000 vac (RMS) @ 100 mA (Ozone Plates Load).
 | 115vac +12%, -9%
 60 Hz
 | Size: 7.55" L x 3.75" W x 5.25" H & four (4) angle brackets on the base for mounting.
 |  
 
 HV Power Transformers (for Ozone
Generators):
 Potted Types
 
| VA Out
 | Model or Series | Output ac voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| (later) | VP3TH1MC | (later) | (later) | (later) |  
| (later) | VP3TH1MD | (later) | (later) | (later) |  
| (later) | VP3TH2MC | (later) | (later) | (later) |  
| (later) | VP3TH2MD | (later) | (later) | (later) |  
| (later) | VP3TH3MC | (later) | (later) | (later) |  
| (later) | VP3TH3MD | (later) | (later) | (later) |  
 
 HV Power Transformers (for Ozone
Generators):
 Oil-Filled Types
 
| VA Out
 | Model or Series | Output ac voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| 195 | 300TH-956 | Secondary start lead is connected
to "ground". 15,000 vac (RMS) @ 13 mA (Ozone Cell Load}.
 | 115vac +12%, -9%
 | Size: 9" L x 5" W x 6.5" H with four (4) 8-32 x 0.5"
long mounting studs
 in the base.
 |  
 
 HV Pulse Transformers (for Dog
Collars):
 
Note:  1)  Input is 8 vdc switched with FET
in flyback mode with "on" time up to 30 milliseconds, maximum, and with
"off" time of
| VA Out
 | Model or Series | Output  voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| 1 | 300-635B | Pulse voltage of 5,000 ±500 volts,
peak when input to transformer primary is turned "off". | See Note 1 | Size: 1" x 0.75" x 0.66". |  
|  | 301TH-103 |  |  |  |  240 milliseconds or more.
 
 
 HV Pulse Transformers (for Electric
Fences):
 
Note:  1)  Input is 600 volt pulse with 50
microsecond pulse width, obtained by discharging a 30 microfarad capacitor
that has been
| VA Out
 | Model or Series | Output voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| N/A | 301TH-060 | 4,000 volt pulse of 50 microsecond width
into a 75 ohm load; and typically an 8,000 volt pulse at no load | See Note 1 | Size: 3.75" L x 2.76" W x 1.77" H. |  
| N/A | 301TH-061 | 4,000 volt pulse of 150 microsecond width into a 75 ohm
load; and typically an 8,000 volt pulse at no load | See Note 2 | Size: 4.13" L x 3.44" W x 2.85" H. |  charged to 600 volts.  Rep rate is about 60 times per minute.
 2)  Input is 600 volt pulse with 150 microsecond pulse width, obtained
by discharging a 50 microfarad capacitor that has been
 charged to 600 volts.  Rep rate is about 60 times per minute.
 
 
 HV Pulse Transformers (for Air
Treatment Units for Produce Storage):
 Open Construction, Varnish-Impregnated Types
 
Notes:  1)  The input is pulses of up to
100 volts maximum, center-tap to either side of primary (alternating),
800 usec fixed width,
| VA Out
 | Model or Series | Output voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| 300 | 300TH-010 | Output voltage pulses of up to 5000 volts,
maximum, with fixed pulse width of 800 usec, and with rep rate of 0 to
500 Hz (variable) based on input pulse rep rate; and into a load of 10
nanofarads shunted by highly non-linear resistive element. | See Note 1 | Size: 5" L x 4" W x 3" H. Start lead of secondary is grounded.
 |  
| 550 | 300TH-014 | Output voltage pulses of up to 5000 volts, maximum, with
fixed pulse width of 800 usec, and with rep rate of 0 to 500 Hz (variable)
based on input pulse rep rate; and into a load of 10 nanofarads shunted
by highly non-linear resistive element. | See Note 1 | Size: 6.25" L x 4.75" W x 3.25" H. Start lead of secondary is grounded.
 |  with rep rate of 0 to 500 Hz using a push-pull driver topology into a center-tapped 
primary winding.
 
 
 HV Pulse Transformers (for Air
Treatment Units for Produce Storage):
 Potted Types
 
Notes:  1)  The input is pulses of up to
100 volts maximum, center-tap to either side of primary (alternating),
800 usec fixed width,
| VA Out
 | Model or Series | Output voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| 550 | 300TH-013 | Output voltage pulses of up to 5000 volts,
maximum, with fixed pulse width of 800 usec, and with rep rate of 0 to
500 Hz (variable) based on input pulse rep rate; and into a load of 10
nanofarads shunted by highly non-linear resistive element. | See Note 1 | Size: 5.25" L x 4.5" W x 3.25" H Start lead of secondary is grounded.
 |  with rep rate of 0 to 500 Hz using a push-pull driver topology into a center-tapped 
primary winding.
 
 
 HV Pulse Transformers (for Air
Treatment Units for Produce Storage):
 Oil-Filled Types
 
Notes:  1)  The input is pulses of up to
100 volts maximum, center-tap to either side of primary (alternating),
800 usec fixed width,
| VA Out
 | Model or Series | Output dc voltage and current ratings | Input Voltage
 | Other
Features or Comments |  
| 550 | 300TH-032 | Output voltage pulses of up to 5000 volts,
maximum, with fixed pulse width of 800 usec, and with rep rate of 0 to
500 Hz (variable) based on input pulse rep rate; and into a load of 10
nanofarads shunted by highly non-linear resistive element. | See Note 1 | Size: 6.75" L x 6" W x 3.85" H. Start lead of secondary is grounded.
 |  with rep rate of 0 to 500 Hz using a push-pull driver topology into a center-tapped 
primary winding.
 |